La importancia del agua en la industria de alimentos vegetales

  1. López-Gálvez, Francisco 1
  2. Gil, Maria Isabel 1
  1. 1 Centro de Edafología y Biología Aplicada del Segura (CEBAS). Consejo Superior de Investigaciones Científicas
Aldizkaria:
Arbor: Ciencia, pensamiento y cultura

ISSN: 0210-1963

Argitalpen urtea: 2020

Alea: 196

Zenbakia: 795

Mota: Artikulua

DOI: 10.3989/ARBOR.2020.795N1011 DIALNET GOOGLE SCHOLAR lock_openSarbide irekia editor

Beste argitalpen batzuk: Arbor: Ciencia, pensamiento y cultura

Laburpena

The fresh produce industry consumes large volumes of good quality water and generates large amounts of wastewater. One of the systems that can be applied to reduce water consumption and water discharge is the reuse of washing water. To carry out the reuse of water without compromising the microbiological and chemical safety of the food, it is necessary to optimize the use of antimicrobial agents. Chlorine has traditionally been the disinfection treatment used by the horticultural industry for washing water. However, its use has the disadvantage of accumulating disinfection by-products, which has led to the study and use of alternative disinfectants such as peroxyacetic acid. In any case, maintaining the microbiological and chemical safety of fresh produce in the washing stage involves the selection of operational limits that must be maintained (e.g., the concentration of disinfectant), as well as the monitoring and control of critical parameters related to disinfection such as the content of organic matter. The optimization of disinfection must take into account the peculiarities of each case, including the type of product washed, the disinfectant used and the design and management of the washing line.

Erreferentzia bibliografikoak

  • Abadias, M., Usall, J., Oliveira, M., Alegre, I., Viñas, I. (2008). Efficacy of neutral electrolyzed water (NEW) for reducing microbial contamination on minimally-processed vegetables. International Journal of Food Microbiology, 123, pp. 151-158.
  • Bornhorst, E. R., Luo, Y., Park, E., Vinyard, B. T., Nou, X., Zhou, B., Turner, E. y Millner, P. D. (2018). Immersion-free, single-pass, commercial fresh-cut produce washing system: An alternative to flume processing. Postharvest Biology and Technology, 146, 124-133.
  • Casani, S., Rouhany, M. y Knøchel, S. (2005). A discussion paper on challenges and limitations to water reuse and hygiene in the food industry. Water Research, 39, pp. 1134-1146.
  • European Food Safety Authority (EFSA) (2015). Risks for public health related to the presence of chlorate in food. EFSA Panel on Contaminants in the Food Chain (CONTAM). EFSA Journal, 13 (6), 4135.
  • Fu, T.-J., Li, Y., Awad, D., Zhou, T.-Y. y Liu, L. (2018). Factors affecting the performance and monitoring of a chlorine wash in preventing Escherichia coli O157:H7 cross-contamination during postharvest washing of cut lettuce. Food Control, 94, pp. 212-221.
  • Gil, M. I., Selma, M. V., López-Gálvez, F. y Allende, A. (2009). Fresh-cut product sanitation and wash water disinfection: Problems and solutions. International Journal of Food Microbiology, 134 (1-2), pp. 37-45.
  • Gil, M. I., Marín, A., Andujar, S. y Allende, A. (2016). Should chlorate residues be of concern in fresh-cut salads? Food Control, 60, pp. 416-421.
  • Gombas, D., Luo, Y., Brennan, J., Shergill, G., Petran, R., Walsh, R., Hau, H., Khurana, K., Zomorodi, B., Rosen, J., Varley, R. y Deng, K. (2017). Guidelines to validate control of cross-contamination during washing of fresh-cut leafy vegetables. Journal of Food Protection, 80, pp. 312-330.
  • Gómez-López, V. M., Lannoo, A.-S., Gil, M. I. y Allende, A. (2014). Minimum free chlorine residual level required for the inactivation of Escherichia coli O157:H7 and trihalomethane generation during dynamic washing of fresh-cut spinach. Food Control, 42, pp. 132-138.
  • Gómez-López, V. M., Gil, M. I., Allende, A., Vanhee, B. y Selma, M. V. (2015). Water reconditioning by high power ultrasound combined with residual chemical sanitizers to inactivate foodborne pathogens associated with fresh-cut products. Food Control, 53, 29-34.
  • Holvoet, K., Jacxsens, L., Sampers, I. y Uyttendaele, M. (2012). Insight into the prevalence and distribution of microbial contamination to evaluate water management in the fresh produce processing industry. Journal of Food Protection, 75, 671-681.
  • Hricova, D., Stephan, R. y Zweifel, C. (2008). Electrolyzed water and its application in the food industry. Journal of Food Protection, 71, pp. 1934-1947.
  • Kaufmann-Horlacher, I., Scherbaum, E., Stroher-Kolberg, D. y Wildgrube, C. (2014). Chlorate residues in plant-based food: Origin unknown. CVUA Sttutgart. [En línea]. Disponible en: http://www.cvuas.de/pub/beitrag. asp?subid=1&ID=1854&Pdf=No
  • Kitis, M. (2004). Disinfection of wastewater with peracetic acid: a review. Environment International, 30, pp. 47-55.
  • López-Gálvez, F., Allende, A., Selma, M. V. y Gil, M. I. (2009). Prevention of Escherichia coli cross-contamination by different commercial sanitizers during washing of fresh-cut lettuce. International Journal of Food Microbiology, 133 (1-2), pp. 167-171.
  • López-Gálvez, F., Allende, A., Truchado, P., Martínez-Sánchez, A., Tudela, J. A., Selma, M. V. y Gil, M. I. (2010). Suitability of aqueous chlorine dioxide versus sodium hypochlorite as an effective sanitizer for preserving quality of fresh-cut lettuce while avoiding by-product formation. Postharvest Biology and Technology, 55 (1), pp. 53-60.
  • López-Gálvez, F., Posada-Izquierdo, G. D., Selma, M. V., Pérez-Rodríguez, F., Gobet, J., Gil, M. I. y Allende, A. (2012). Electrochemical disinfection: An efficient treatment to inactivate Escherichia coli O157:H7 in process wash water containing organic matter. Food Microbiology, 30 (1), pp. 146-156.
  • López-Gálvez, F., Tudela, J. A., Allende, A. y Gil, M. I. (2019). Microbial and chemical characterization of commercial washing lines of fresh produce highlights the need for process water control. Innovative Food Science and Emerging Technologies. Innovative Food Science and Emerging Technologies, 51, pp. 211–219.
  • Luo, Y., Nou, X., Yang, Y., Alegre, I., Turner, E., Feng, H., Abadias, M. y Conway, W. (2011). Determination of free chlorine concentrations needed to prevent Escherichia coli O157:H7 cross- contamination during fresh.cut produce wash. Journal of Food Protection, 74 (3), pp. 352-358.
  • Manzocco, L., Ignat, A., Anese, M., Bot, F., Calligaris, S., Valoppi, F. y Nicoli, M. C. (2015). Efficient management of the water resource in the fresh-cut industry: Current status and perspectives. Trends in Food Science and Technology, 46, pp. 286-294.
  • Mena, K. D. (2006). Produce quality and foodborne disease: Assessing water’s role. En: James, J. A. (ed.). Microbial hazard identification in fresh fruits and vegetables. Hoboken, NJ: Wiley, pp. 95-114.
  • Munther, D. y Wu, J. (2013). Enhanced surveillance on food-borne disease outbreaks: Dynamics of cross-contamination in biocidal wash procedure. Journal of Theoretical Biology, 321, pp. 28-35.
  • Ölmez, H.y Kretzschmar, U. (2009). Potential alternative disinfection methods for organic fresh-cut industry for minimizing water consumption and environmental impact. LWT- Food Science and Technology, 42, pp. 686-693.
  • Selma, M. V., Allende, A., López-Gálvez, F., Conesa, M. A. y Gil, M. I. (2008a). Heterogeneous photocatalytic disinfection of wash waters from the fresh-cut industry. Journal of Food Protection, 71, pp. 286-292.
  • Selma, M. V., Allende, A., López-Gálvez, F., Conesa, M. A. y Gil, M. I. (2008b). Disinfection potential of ozone, ultraviolet-C and their combination in wash water for the fresh-cut vegetable industry. Food Microbiology, 25 (6), pp. 809-814.
  • United States Food and Drug Administration (USFDA) (2001). Analysis and Evaluation of Preventive Control Measures for the Control and Reduction/Elimination of Microbial Hazards on Fresh and Fresh-cut Produce. Report of the Institute of Food Technologists. IFT/FDA Contract No. 3.
  • Van Haute, S., López-Gálvez, F., Gómez- López, V. M., Eriksson, M., Devlieghere, F., Allende, A. y Sampers, I. (2015). Methodology for modeling the disinfection efficiency of fresh-cut leafy vegetables wash water applied on peracetic acid combined with lactic acid. International Journal of Food Microbiology, 208, pp. 102-113.
  • Directiva 98/83/CE del Consejo de 3 de noviembre de 1998 relativa a la calidad de las aguas destinadas al consumo humano. Diario Oficial de las Comunidades Europeas, 5 diciembre 1998. Disponible en https://eur-lex.europa.eu/legal-content/ES/ALL/?uri=celex%3A31998L0083
  • Nota de la Comisión sobre la Guía para combatir los riesgos microbiológicos en frutas y hortalizas frescas en la producción primaria mediante una buena higiene. Diario Oficial de la Unión Europea, 23 mayo 2017. Disponible en https://eur-lex.europa.eu/legal-content/ES/ALL/?u ri=CELEX%3A52017XC0523%2803%29
  • Reglamento (CE) n° 852/2004 del Parlamento Europeo y del Consejo, de 29 de abril de 2004, relativo a la higiene de los productos alimenticios. Diario Oficial de la Unión Europea, 30 abril 2004. Disponible en https:// eur-lex.europa.eu/legal-content/ES/ ALL/?uri=CELEX%3A32004R0852
  • Chlorine and its oxides: Chlorate and perchlorate review. AHDB. [En línea]. Disponible en: https://ahdb.org.uk/ cp-154a-chlorine-and-its-oxides-chlorate-perchlorate-review
  • Whitaker, B. Key Learnings from CPS Wash Water Symposium. [En línea]. Disponible en: https://www.centerforproducesafety.org/amass/documents/ document/118/Key%20Learnings%20 from%20CPS%20Wash%20Water%20 Symposium%20January%202013.pdf